°úÇбâÀÚÀçÀü½Ã½Ç | °ßÀûÀÇ·Ú | ¹ÌµîÀç»óÇ°»ó´ã | ¼öÃâÀÔ ¹× Á¦Á¶»ó´ã | ½ÇÇè»ó´ã | Çù·Â¾÷ü¹®ÀÇ
X-ray Micro CT Scanner
 

 

  ¡æ  »óÇ°»ó¼¼Á¤º¸  

 

X-ray Micro CT Scanner

 

(Model: Harmony 90H-P3-5) 

  

 A. Configurations

 

1. Shield Cabinet                                                : 1 set

2. X-ray Source                                                  : 1 set

3. Detector                                                      : 1 set

4. Workstation                                                   : 1 set

5. Software                                                     : 1 set

6. Documents                                                    : 1 set

7. Accessories                                                   : 1 set


  B. Specifications

 

1.    System

- Dimension: Approx. 860 x 520 x 420 (D x W x H) mm3

- Weight: approx. 140kg

- Radiation Shield Cabinet including Lead Glass Window:  ¡Â 1uSv/h @ Full kVp/mA

 

2. Field of Views (=FOV)

- FOV variable by magnification

- Max. Magnification by geometry: 30

- Maximum FOV : Dia. 80mm.

- Stroke: Max. 239mm

- Distance of Source to Detector : 300mm

 

3. X-ray Source

- Integrated X-ray tube and Power supply

- Tube Voltage Range: 20~90kV

- Anode Current: 0~200uA

- Max. Power: 8watts   

- Focal Spot Size: Min.5um (nominal per IEC336, JISZ47045, NEMA XR5)

- Target Material: Tungsten    

- Control through RS232C

- Operating Temperature / Humidity: 10~35¡É / Max.95%

 

4.    Flat Panel X-ray Detector

- Detector element: 1024 x 2048 pixels

- Pixel Pitch : 48um    

- Active Area; 49.2 x 98.3 mm

- 12 bit data output

- Interface Cable length: Standard 3m

 

5.  Recon. Image size

- 512 x 512 x 512, 1024 x 1024 x 1024

- Reconstruction time@ 512 x 512 x 512 , 400views < 10minnutes

- Spatial Resolution > 5um

 

6.    Motion Axis

- Number of Motion: 2 axis(Rotation, Holizontal linear motion)

- Rotation for an object to be scanned

- Maximum Object Weight load on Rotation Stage: 3kgf

- View Number: 400, 800 selectable

- Horizontal movement for magnification: Stroke Max.239mm

      

7. Workstation

- 2 CPU, 64 bit Quad-Core Intel(R) Xeon(R) E5345 2.33GHz/1333Mhz/2 x 4M L2 Cache

- OS: MS windows Vista 64bit

- RAM: 16GB(2X8GB) Quad-channel DDR2 full buffer DIMM (FBD)667MHz ECC

- Hard Disk: 500GB SATA (7,200RPM) x 2EA, RAID 1.

- Optical Device: 16X max DVD+/-RW Drive  

- Vidio Card: 256MB PCI , Dual_DVI ports.

- Monitor: 20" UltraSharp¢â Digital LCD Monitor 1600x1200, 1 EA

- Internal Speakers, Mouse, Key board  

- Frame Grabber for x-ray detector

 

8. Software

- CT Software (Harmony90H): 1 set, including

 1) Application program for system operating

 2) For calibration

 3) For CT image reconstruction

- 3D Software (iCAT3D): 1 set, including

1) Rendering: MRP/MIP/minIP/VR

2) View: Pan/Rotate/Zoom/Windowing/Invert etc

3) Measurement

Ruler/ Tape line(Line type, Curve type) /

Angle(3-Point Click, 4-Point Click, 3D Angle)

Profile: graph of intensity

Area(Line pen, Curve pen, Smart pen), Information of ROI

4) Segmentation 

5) Fine Tuning

6) Output file: bmp, jpg, tif, png/avi/DICOM

 

9. Documents supplied

-  Instruction / Operation Manual: 1set

 

10. Accessories

- Phantom for Rotation Center Calibration: 1 set 

 

C. Utilities : User¡¯s preparations

-     Required Electric power: single phase 220VAC(within 10%), 2kVA

-     Grounding: D class grounding (Less than 100 Ohms)

-    Environmental condition (in operation)

 Temperature: 10 to 30 ¡É

 Humidity: Less than 80% (no dew condensation)

 Vibration, dust and gas to be free